Total Access 5000 Business Services Deployment Guide
4-10 65K510DEP08-1A
NOTE
Thisinformation is sent to the NetVanta 838 by wa y of an overhead
managementchannel.
OncecompletedandifthemanagementVLANsoftheGigESMandtheNetVanta838are
equivalent,theNetVanta838CommandLineInterface(CLI)canbeaccessedviatheInband
ManagementVLAN.
Modify an Existing Bridge
TherearetwowaystomodifyanexistingEFMbondinggroup.TheEZEFMapplication
allowstheusertoaddorremovealinkto/fromabondinggroupwhilesimultaneouslyspeci
fyingthebondinggroupupstreamanddownstreamdatarates.TheEZEFMapplication
automaticallyreprovisionsalllinksinthe
grouptothenecessarylinkrates,whethertherate
isincreasedordecreased.Thelinksretainandprovidetheprovisioneddatarate.
Thesecondwaytoaddorremovealinkto/fromagroupisbydirectlymodifyingtheEFM
bondinggroupintheEFMBondingGroupConfigurationprompt.Thismethod
doesnot
resultinareprovisioningofthelinksinthegroup, butcanresultinthelinksnotbeingsetto
theoptimumrates;thegroupnotprovidingthespecifieddatarateiflinksareremoved.
Modify a Bonding Group with EZ-EFM
TomodifyabondinggroupusingtheEZEFMapplication,completethefollowingprocedure:
1. FromtheEnableprompt,type
applicationandpressENTERtoaccesstheapplication
CLIprompt.
2. FromtheApplication Configurationprompt,type
ez-efm 1and pressENTERtostartthe
EZEthernetapplication.
3. FromtheEFMConf igurationprompt,type
modify <group_name> link <slot/
port> upstream <0-250000> downstream <0-250000> active-links-minimum
<1-n>
, andpressENTERtomodifyanexistingEFMBondingGroup.
RefertoTable45forthelistofvariablesfortheEFMbondinggroup.
4. FromtheEFMConf igurationprompt,type
modify <group_name> no-link <slot/
port> upstream <0-250000> downstream <0250000> active-links-minimum
<1-n>
,andpressENTERtoremovelinksfromanexistingEFMBondingGroup.
NOTE
Forthe modifycommand,allparameters mustbe specified, evenifa
particularvalueisnotbeingchanged.
RefertoTable45forthelistofvariablesfortheEFMbondinggroup.
5. FromtheEFMConf igurationprompt,type
exit,andpressENTERtoreturntothe
ApplicationConfigurationprompt.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN TA 5000 and is the answer not in the manual?

ADTRAN TA 5000 Specifications

General IconGeneral
BrandADTRAN
ModelTA 5000
CategoryNetwork Router
LanguageEnglish

Related product manuals