Total Access 5000 Business Services Deployment Guide
J-6 65K510DEP08-1A
Provision the Timing Source
Toprovisionthetimi ngsource,completethefollowing:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo‐
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
system-timing <shelf>,andpress
ENTER.
3. FromtheSystem‐TimingConfigurationprompt,type
source primary loop-a
interface t3 <shelf/slot/port>
,andpressENTER.
4. FromtheSystem‐TimingConfigurationprompt,typesource secondary loop-b
interface t3 <shelf/slot/port>
,andpressENTER.
ADTRANrecommendshavingtheprimaryandsecondarytimingsourceson
differentDS3portsandadjacentredundantslots.
Provision the T1 8-Port Line Module
Thissubsectiondetailsthefollowing information:
•T18‐PortLineModuleProvisioningDefaults
• AccesstheT18‐PortLineModule
•ProvisiontheT18‐PortLineModuleServiceState
•ProvisiontheT18‐PortAccessLineModuleDS1InterfaceServiceState
•ProvisiontheUplinkIdentifier
•ProvisiontheDS1Interface
T1 8-Port Line Module Provisioning Defaults
WhentheT18‐PortLineModuleisinstalledinaTotalAccess5000shelf,theSCMqueriesthe
system(localandclusteredshelves)tosynchronizeitsdatabase.Nouserinterventionis
requiredforthisprocess.ProvisioningishandledwithoutuserentryifAuto‐Provisioningis
enabled.Otherwise,provisioningmustbe
accomplishedmanuallythroughtheSCMmenu
system.
TableJ‐4showstheminimumlistoffactorydefaultsandvaluesthatareloadedafterinstal‐
lationandself‐test.Thesedefaultsandvaluesprovidetheminimumconfigurationforturnup
oftheT18‐PortLineModule.