Appendix H, Alarm Severities - T1 Alarm Severity Level
65K510DEP08-1A H-3
T1 Alarm Severity Level
TosetthealarmseveritylevelforaT3alarm,completethefollowingsteps:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo‐
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
interface t1 <shelf/slot/
port:channel>
,andpressENTERtoaccesstheT1Configurationprompt.
3. FromtheT1Configurationprompt,type
alarm level <alarm_name>
<alarm_level>
,andpressENTERtosetthealarmseveritylevel.RefertoTableH‐4for
validalarm_na meandalarm_levelvalues.
TableH‐4displaystheT3ParameterValues.
4. FromtheT1Configurationprompt,provisionthealarmstatusbyperformingoneofthe
followingcommands:
•Type
no alarm enable <alarm_name>,andpressENTERtodisablethespecified
alarm
•Type
alarm enable <alarm_name>,andpressENTERtoenablethespecifiedalarm
5. FromtheT1Configurationprompt,type
end,andpressENTERtoreturntotheEnable
prompt.
Table H-3. T3 Parameter Values
alarm_name alarm_level
LOS Critical
LOF Major
RAI Minor
AIS Alert
Information
Table H-4. T1 Parameter Values
alarm_name alarm_level
LOF Critical
RAI Major
AIS Minor
Alert