Total Access 5000 Business Services Deployment Guide
4-6 65K510DEP08-1A
Provision the EFM Bonding Protection Module
Administration State
FortraffictobeprotectedintheeventofanEFMbondingenginefailure,theEFMBonding
ProtectionModulecardservicestatemustbesettoISorOOS‐MA.Thedefaultservicestate
forthe32‐PortSHDSLEFMEFMisOOS‐MA.
IfthecardservicestateissettoOOS‐MA,normaloperationoccursbutalarms
arenotreported.
Tosetthecardservicestate,completethefollowingprocedure:
Table4‐4displaysthethreeadministrationstates.
Tosetthecardservicestate,completethefollowingprocedure:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo‐
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,provisiontheadministrationstateby
performingoneofthefollowingcommands:
•Type
no slot shutdown <shelf/slot>,andpressENTERtotaketheslotInService
•Ifconnectedtotheshelfwherethemoduleresides,theshelfnumberis
typically1.
•Thisistheslotofthemodulebeingconfigured.Validvaluesare
1–11and13–22.
•Type
slot shutdown maintenance <shelf/slot>,andpressENTERtotakethe
slotOutofService,Maintenance
•Type
slot shutdown <shelf/slot>,andpressENTERtotaketheslotOutof
Service,Unassigned
3. Type
end,andpressEntertoreturntotheEnableprompt.
Table 4-4. EFM Bonding Protection Module Administration States
Command Previous Description
no shutdown
InService
Inthe no shutdownstate,trafficpasses
andalarmsaregenerated.Thisisthe
defaultvalue.
shutdown maintenance
OutofService,
Maintenance
Intheshutdown maintenancestate,
trafficpassesbutnoalarmsaregenerated.
shutdown
OutofService,
Unassigned
Inthe shutdownstate,notrafficpasses
andnoalarmsaregenerated.