Section 4, EoCu Provisioning - Disable Unused NetVanta 838 Interfaces
65K510DEP08-1A 4-33
Disable Power Feed Alarms
Todisablethepowerfeedalarms,completethefollowingprocedure:
Apowerfeedinputcannotbedisabled,butifbothinterfacesarenotbeing
sourcedwith±48VDCor ±24VDCpowering,thereisapowerfailalarm
activefortheunusedinput.
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo‐
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,accessthesystemalarmpromptbytyping
system-alarm,andpressENTER.
3. IfpowerfeedAisunused,disablethepowerfeedAalarmbytyping
no alarm enable
power-fail dc a
,andpressENTER.
4. IfpowerfeedBisunused,disablethepowerfeedBalarmbytyping
no alarm enable
power-fail dc b
,andpressENTER.
5. Type
end,andpressENTERtoreturntotheEnableprompt.
ThepowerAorBfailalarmshouldbeclearedinthealarmlog.
Onceallunusedinterfacesaredisabled,thealarmsfortheseinterfacesshouldnowbecleared.
Ifallin‐useinterfaces(SHDSL,Ethernet,Gigabit‐Ethernet,andpower)areinnon‐alarmed
states,
thentheAlarmLEDontheNetVanta838shouldnowbelitsolidgreen.
Clear the Alarm Log
BeforeclearingtheAlarmLog,thealarmsmustfirstbeacknowledged.
TocleartheAlarmLog,completethefollowingprocedure:
1. FromtheEnableprompt,type
force alarm acknowledge,andpressENTER.
2. Clearthealarmlogbytyping
force alarm clearandpressingENTER.
3. Verifytherearenoalarmsbytyping
show alarm logandpressingENTER.