Total Access 5000 Business Services Deployment Guide
J-10 65K510DEP08-1A
Remote Terminal (RT) Provisioning
ToprovisiontheRT,completethefollowing:
•ProvisiontheGigESM
Formoreinformation,referto“ProvisiontheGigESM”onpage J‐10.
•ProvisiontheGE4‐PortLineModule
Formoreinformation,referto“ProvisiontheGE4‐PortLineModule”onpage J‐11.
•ProvisiontheDS3UnchanelizedEFM4‐PortLine
Module
Formoreinformation,referto“ProvisiontheDS3UnchannelizedEFM4‐PortLine
Module”onpage J‐13.
•ProvisiontheT18‐PortLineModule
Formoreinformation,referto“ProvisiontheT18‐PortLineModule”onpage J‐15.
Provision the GigE SM
Thissubsectiondetailsthefollowing information:
•ProvisiontheTimingSource
Provision the Timing Source
Tosetthetimingsources(primaryandsecondary)toBITS,completethefollowing:
Theprimaryandsecondarytimingsourcescanbedifferentdependingonthe
configuration.
1. FromtheSwitchModulemenu,select
Provisioning,andpressENTER.
2. FromtheProvisioningmenu,select
Timing,andpressENTER.
3. FromtheTimingmenu,select
Primary Source,andpressENTER.
ThePrimarySourceprovisionsthelocalinputfortheprimaryclockgeneration.
4. FromthePrimaryTimingSourcemenu,select
Net 1,andpressENTER.
5. FromtheTimingmenu,select
Secondary Source,andpressENTER.
TheSecondarySourceprovisionsthelocalinputforthesecondaryclockgeneration.
6. FromtheSecondaryTimingSourcemenu,select
Local,andpressENTER.