Section 4, EoCu Provisioning - Create an EFM Bonding Group
65K510DEP08-1A 4-9
Loopback : Disabled
XCV Threshold : 1e-7
XCV Link Removal : Enabled
TA5000#
Configure EFM Bonding Management Provisioning
TheNetVanta838InbandManagementconfigurationistiedtotheEFMbondinggroup.
Thus,whenaNetVantaisreplaced,theremotemanagementconfigurationispusheddownso
thattheNetVantaisimmediatelyremoteaccessiblewhenatleastoneSHDSLlinksynchro
nizes.
NOTE
Ifprovisioning the NetVanta 838locally,theTotalAccess5000overwrites
theInbandmanagementprovisioningwhentheSHDSLportssynchronize
withtheSHDSLEFMaccessmodule.
TheInbandmanagementoftheNetVanta 838isco nfiguredattheTotal
Access 5000, and pushed down to the NetVanta 838 as soon as
synchronizationisachievedononeofthelinksofthebondedgroup.
ToconfiguretheEFMbondinggroupmanagementprovisioning,completethefollowing
procedure:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
interfaceefm-group <shelf/slot/
group>
,andpressENTERtoaccesstheEFMBondingGroupConfigurationprompt.
3. FromtheEFMGroupInte rface Configurationprompt,type
subtended-host ip
address A.B.C.D E.F.G.H
,andpressENTERtoprovisiontheNetVantaManagement
IPaddress(A.B.C.D)andsubnetmask(E.F.G.H).
4. FromtheEFMGroupInte rface Configurationprompt,type
subtended-host s-tag
<1-4094>
,andpressENTERtoprovisiontheNetVantaManagementVLAN.
5. FromtheEFMGroupInte rface Configurationprompt,type
subtended-host ip
default-gateway A.B.C.D
,andpressENTERtoprovisiontheNetVantaManagement
Gateway.
6. FromtheEFMGroupInte rface Configurationprompt,type
subtended-host ip
file-server default host A.B.C.D
,andpressENTERtoprovisiontheNetVanta838
ManagementTFTPserver.
7. FromtheEFMGroupInte rface Configurationprompt,type
subtended-host snmp-
server chassis-id WORD
,andpressENTERtoprovisiontheNetVantaSNMPsystem
name.
8. FromtheEFMGroupInte rface Configurationprompt,type
subtended-host snmp-
server community read-only WORD
,andpressENTERtoprovision thereadonly
SNMPcommunity.
9. FromtheEFMGroupInte rface Configurationprompt,type
subtended-host snmp-
server community read-write WORD
,andpressENTERtoprovisionthereadwrite
SNMPcommunity.
10. FromtheEFMGroupInterfaceConfigurationprompt,type
end,andpressENTERto
returntotheEnableprompt.