Total Access 5000 Business Services Deployment Guide
5-4 65K510DEP08-1A
Provision the Line Module
Thissectiondetailsprovisioningforthefollowingmodules:
•CHDS3PPP/MLPPP3PortLineModule
•DS1PPP/MLPPP32PortLineModule
Provision the CH DS3 PPP/MLPPP 3-Port Line Module
Administration Status
TheCHDS3PPP/MLPPP3PortLineModulecardservicestatemustbesettoInService,Out
ofService,orOutofServiceMaintenance.
NOTE
IfthecardservicestateissettoOutofServiceMaintenance,normal
operationoccursbutalarmsarenotreported.
LinecodeandlinebuildoutcannotbeprovisionedforeithertheDS3or
DS1.
Fortraffictopass,theCHDS3PPP/MLPPP3PortLineModulemustbeenabled.
Table52displaysthethreeadministrationstatesandshowstheequivalentServiceStatefrom
priorreleases.
Tosetthemoduleadministrationandportadministrationstates,completethefollowing
procedure:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo
balConfigurationprompt.
NOTE
Ifconnectedto the shelfwherethemoduleresides,theshelfnumberis
typically1.
Table 5-2. Line Module Administration States
Command Previous Description
no shutdown
InService
Inthe no shutdownstate,trafficpasses
andalarmsaregenerated.
shutdown maintenance
OutofService,
Maintenance
Intheno shutdownstate,trafficpasses
butnoalarmsaregenerated.Alarmsare
suppressedandnoevidenceofthealarm
isshown.
shutdown
OutofService,
Unassigned
Inthe
no shutdownstate,notraffic
passesandnoalarmsaregenerated.