Total Access 5000 Business Services Deployment Guide
F-4 65K510DEP08-1A
EVCs
TheMEFdefinesanEVCas“anassociationoftwoormoreUNIs,”whereaUNIisastandard
10/100/1000EthernetinterfacethatisthepointofdemarcationbetweentheCEandtheMEN
oftheserviceprovider.Insimpleterms,anEVCperformstwofunctions.
Connectstwoormoresubscriber
sites(UNIs)enablingthetransferofEthernetservice
frames
•PreventsdatatransferbetweensubscribersitesthatarenotpartofthesameEVC
ThiscapabilityenablesanEVCtoprovidedataprivacyandsecuritysimilartoaFrame
RelayorATMPermanentVirtualCircuit(PVC).
MultipleEVCscanresideonacommon
bondinggrouporEthernetport.EachEVChasan
associatedEVCwhoseVLANIDisunique amongotherEVCsintheMEN.TheEVCstag
allowstheEVCtobeidentifiedandseparatedfromotherEVCswithintheMEN.TheEVCs
tagexistsonlywithintheMENandis
nottransmittedfromorreceivedattheCE.
TheMEFdefinesEthernetLine(ELine)servicesasaservicethatprovidesapointtopoint
EVCthatconnectsexactlytwoUNIs.
EVC Attributes
TheattributesofanEVCaredescribedinthefollowingparagraphs.
Name
ThisattributeisanarbitrarystringthatisusedtoidentifytheEVCwithintheMEN.Thevalue
mustbeuniqueacrossallEVCsdefinedinthenetworkelement,andisintendedfor
managementandcontrolpurposes.ThevalueisnotcarriedinanyfieldintheEthernetframe.
Asan
example,theAcmeServiceProvidercanuse“EVC0001898ACMEMEGAMA RT”to
representthe1898thEVCintheMEN.Inthisexample,thecustomerfortheEVCisMegaMart.
Configuration Status
Thisreadonlyattributeind icatesthecurrentstatusoftheEV C.TheEVCcanbeadministra
tivelyenabled,butcannotbeinthefunctionalstateifitisnotfullyconfiguredorifaconflict
exists.IftheEVCisnotappliedduetotheconfig urationoraconflict,refer
toTableF 3fora
listsofthepossiblevalues.
Table F-3. EVC Status Values
Possible Values Definition
Running ConditionsareokayandtheEVCprovisioningisapplied.
MissingConnection TheEVCisnotconnectedtoenoughactiveinterfaces.Themini
mumrequiredistwo.Theactiveinterfacecanbedirectlycon
nectedbyMENportormappedUNI.
TagConflict AnotherEVCisadministrativelyenabledandconfiguredtouse
thesame
stag.
Disabled TheStatevalueoftheEVCisprovisionedasdisabled.
SystemmanagementevcCon
flict
TheEVCstagisinusebythesystemmanagementEVC.