Total Access 5000 Business Services Deployment Guide
L-4 65K510DEP08-1A
Access the RPR Line Module
ToaccesstheRPRLineModule,completethefollowing:
1. FromtheTotalAccess5000Mainmenu,select
Module Menus,andpressENTER.
2. FromtheModuleMenusmenu,select
RPR LM,andpressENTER.
FigureL‐3displaystheRPRLineModuleMainmenu.
WaittoRestoreTime(s) 0–1140seconds 10s
ProtectionHoldoffTime(ms) 0–500milliseconds 0s
ProtectionCommand ForceSwitch;
ManualSwitch;
Idle
Idle
FairnessWeight 1;
2;
4;
8;
16;
32;
64;
128
1
AllowAnySFP
AllowAnySFP Yes;
No
No
SystemTiming
Timing None;
SetTimingtoLoopA;
SetTimingtoLoopB
None
MulticastVLANProvisioning
MulticastVLANValue 1–4094 0
MulticastVLANEnable Yes;
No
No
Hub/SpokeMode
Hub/SpokeMode Hub;
Spoke
Hub
Table L-2. Default Provisioning Options (Continued)
Provisioning Option Available Options Default Setting