Total Access 5000 Business Services Deployment Guide
G-6 65K510DEP08-1A
Valid<command_type>valuesarecsu,fdl,andfeac.
•Type
no remote-loopback,andpressENTERtoprovisiontheporttoignoreremote
loopbackcommands.
Valid<command_type>valuesarecsu,fdl,andfeac.
4. FromtheT1InterfaceConfigurationprompt,type
end,andpressENTERtoreturntothe
Enableprompt.
Test Administrative Functions
TheTotalAccess5000CLIApplicationprompt,controlsboththelocalloopbackandBERT
functions.WhileintheApplicationprompt,thefollowingcommandscanbeissued:
•ViewthecurrentteststatusoftheDS3interfacebytyping
show test interface t1
<shelf/slot/port:channel>
,andpressENTER
•CleartheteststatisticsoftheDS3interfacebytypingtest interface t1
<shelf/slot/port:channel> clear
,andpressENTER
•Stopanytestinprogress(loopbackorBERT)bytypingno test interface t1
<shelf/slot/port:channel>
,andpressENTER
Local Line Loopback Configuration
ToconfigurelocalDS3loopbacks,completethefollowingsteps:
1. FromtheEnableprompt,type
application,andpressENTERtoaccesstheApplication
prompt.
2. FromtheApplication prompt,type
test interface t1 <shelf/slot/
port:channel> local loopback line timeout <0-9999>
,andpressENTERtostart
aDS1lineloopback.
•Theloopbacktimeoutisoptionalandcanbeleftofftheloopbackcommand
•TheDS3lineloopback canbestoppedbytypingno test interface t1
<shelf/slot/port:channel>,andpressENTER
BERT Test Configuration
TheChannelizedDS3Multi‐Service3‐PortperformsBERTgenerationandtestingattheDS3
interfaces.ToconfiguretheDS3BERT,completethe followingsteps:
1. FromtheEnableprompt,type
application,andpressENTERtoaccesstheApplication
prompt.