Appendix C, Ethernet OAM Provisioning - Ethernet OAM on the MSAP (Total Access 5000)
65K510DEP08-1A C-11
Ethernet OAM on the MSAP (Total Access 5000)
ToconfigureEthernetOAMontheTotalAccess5000,completethefollowing:
1. EnableEthernetOAMontheTotalAccess5000.
2. CreatetheMDandMA.
TheMDcontainsthefollowingattributes:
• Domainname
• Domainlevel
• Associationname
• ComponentVLANnumber
3. CreateaMIPonaVLAN.
4. CreateaMEPontheTotalAccess5000.
Enable Ethernet OAM on the Total Access 5000
ToenableEthernetOAMontheTotalAccess5000,completethefollowing:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo‐
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
ethernet cfm,andpressENTERtoenable
CFMsubsystemontheTotalAccess5000.
Create the Maintenance Domain and Association
TocreateanMDandassociation,andtoassociateaVLANwiththeassociation,completethe
following:
1. FromtheEnableprompt,type
configure terminal,andpressENTERtoaccesstheGlo‐
balConfigurationprompt.
2. FromtheGlobalConfigurationprompt,type
ethernet cfm domain char-string
WORD level <0-7>
tocreatetheethernetMDatleveldomain_level.
3. FromtheEthernetOAMDomainConfigurationprompt,type
association char-
string WORD
tocreatethemaintenanceassociation.
4. FromtheEthernetOAMAssociationConfigurationprompt,type
component 1 vlan
<1-4094>
toadd(associate)theVLANtotheMA/MD.
5. Type
exit,thenpressENTER,toexittheAssociationConfigurationprompt.
6. Type
exit,thenpressENTER,toexittheDomainprompt.