Page 248 – 13. User Settings and other options
TitanUniversal_Man_v10_QU.doc 15 March 2016
LED Programmer Level: Level if fixture is in the programmer.
LED Selected Level: Level if fixture is selected.
13.5.12 Timecode
Kill Out of Range Playbacks:
MIDI Device ID: Sets the Device ID when using MIDI show control
commands.
MIDI Glitch Detection: Enables the glitch options below.
MIDI Glitch Tolerance: Sets the maximum amount of time a MIDI
timecode can jump by without being seen as a glitch.
MIDI Glitch Timeout: Sets the amount of time the console should
ignore MIDI timecode for after a glitch has been detected.
13.5.13 Wheels
Wheel Sensitivity: The sensitivity of the encoder wheels, and the
pan/tilt threshold settings can be adjusted using this option. Wheel
sensitivity is adjusted using Wheel A and the current level is shown
on the display.
Pan & Tilt Threshold: Enables or disables the pan/tilt threshold
options below.
Pan Threshold: Sets the sensitivity of the Pan control if above
option enabled. Larger numbers make Pan work slower.
Tilt Threshold: Sets the sensitivity of the Tilt control if above option
enabled. Larger numbers make Tilt work slower.
Auto Connect: sets whether Chases and Cue Lists will auto-connect
to the wheels when the playback is fired. The options are [Off],
[Chases], [Lists] and [Chases and Lists].
Press and Hold Fan: [Press and Hold Fan] changes the Fan
function so that it only works while the Fan button is held. This avoids
the common user error of leaving Fan turned on accidentally.
13.6 DMX output mapping
There are various ways to connect fixtures to the console. As well as
the XLR sockets on the console, you can connect fixtures using
Ethernet and wireless links.
The console itself can output up to 12 universes of DMX. “Pro”
versions of consoles can output 16 universes. Titan One outputs one
single universe.
If you need to output more universes, it is recommended to network
the console to one or more Avolites TitanNet processing nodes. This
off-loads the DMX processing, allowing the console to control up to 64
universes of DMX in total.
• The software will allow you to configure more than 12 universes
from a single console but performance of the console will be
degraded. A warning will be shown in the processing load
section of the TitanNet overview.