Configuration
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
106
of 814
3.4
128.1 Motor temperature status
Status of the motor temperature measurement and monitoring:
128.2 Temperature acquisition system
This parameter is used to switch the motor temperature detection and monitoring on and
off, and also the determine the connection to the device.
128.3 Motor temperature
Display of the measured motor temperature in °C
Is important if the motor temperature monitoring is switched on (value Z128.2– bits 0 to
7 ≠ 0 and 1 and 3), only.
Bit Meaning
0 0: Motor temperature monitoring switched off
1: Motor temperature monitoring switched on
3 ... 1 Reserved
4 1: Warning threshold 1 exceeded
5 1: Warning threshold 2 exceeded
6 1: Switch-off temperature reached
7 1: Overtemperature detected by temperature switch
8 1: Short circuit detected on temperature encoder
9 1: Temperature encoder is not connected
15 ... 10 Reserved
Bit Meaning
7 ... 0 Selection of the connection for the motor temperature encoder:
0: No encoder, or motor temperature monitoring off
1: Connection to encoder input, standard connection
2: Connection to encoder input, non-standard connection
3: Connection to power unit
4 … 255 reserved
15 ... 8 Reserved