3
128.4 Warning threshold 1
Motor temperature threshold 1. If the motor temperature exceeds this value, Warning 710
is generated.
128.5 Warning threshold 2
Motor temperature threshold 2. If the motor temperature exceeds this value, Warning 711
is generated.
128.7 Motor temperature hysteresis
Hysteresis for canceling Warnings 710 and 711 initiated by Z128.4– Warning threshold
1 and Z128.5– Warning threshold 2.
133.14 Status motor operating mode
The mode is set in parameter Z19.52–.
Value Meaning
0 Motor observer off
1 Motor observer on
2 Motor model for the motor control