EasyManua.ls Logo

Baumuller b maXX BM5800 - Page 107

Baumuller b maXX BM5800
816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
107
of 814
3
128.4 Warning threshold 1
Motor temperature threshold 1. If the motor temperature exceeds this value, Warning 710
is generated.
128.5 Warning threshold 2
Motor temperature threshold 2. If the motor temperature exceeds this value, Warning 711
is generated.
128.7 Motor temperature hysteresis
Hysteresis for canceling Warnings 710 and 711 initiated by Z128.4 Warning threshold
1 and Z128.5 Warning threshold 2.
133.14 Status motor operating mode
The mode is set in parameter Z19.52.
Value Meaning
0 Motor observer off
1 Motor observer on
2 Motor model for the motor control

Table of Contents

Related product manuals