Configuration
Parameter manual b maXX BM5800
Document No.: 5.16029.03 Baumüller Nürnberg GmbH
96
of 814
3.4
19.52 Modus motor operating mode
The current status is displayed in Z133.14–.
19.61 Delay reference current
Additional delay of the current set value in ms.
Is required with motor having several windings for the master, refer to Z 3.4.6.9–.
107.1 Version
Version of the data structure.
107.2 Motor type
Motor type as a character string, e.g.: "DS 71-K".
107.3 Article number
Article number of the motor on motors with an electronic identification plate. The value
displayed is read from motors with an electronic identification plate and is for information
only.
107.4 Serial number
Serial number of the motor. The value displayed is read from motors with an electronic
identification plate and is for information only.
Value Meaning
0 With encoder, observer off
1 With encoder, observer on
2 Motor model for the motor control (sensorless)