EasyManua.ls Logo

Baumuller b maXX BM5800 - Page 111

Baumuller b maXX BM5800
816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
111
of 814
3
138.4 Quadrant hysteresis Iq limit
Hysteresis for current and speed for assessing the operating quadrants.
Standardization:
100% = Motor nominal torque current Z19.10
or
100% = (Motor) Nominal speed Z107.7
138.5 Motor quadrant
Display of the currently determined quadrant, using the current speed, the instantaneous
current and the set hysteresis.
The following diagram illustrates the definition:
Figure 39: Definition of the quadrants
138.6 Iq upper limit
Display of the currently determined upper limit for the instantaneous current [in A].
138.7 Iq lower limit
Display of the currently determined lower limit for the instantaneous current [in A].
138.8 Bitmask of external drive current limit
Display of external sources of the drive current limit as a bit string.
A 1 in the corresponding bit position means that the limit is active.
If several bits are set, the smallest limit takes effect.

Table of Contents