Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
119
of 814
3
146.13 Flux set value
Set value of the flux in percent
146.14 Actual flux
Actual value of the flux in percent
146.16 Slip preset value
(this is relevant at asynchronous motors with encoder, only)
Slip preset value between electrical and mechanical frequency [Inc/Tab].
It is calculated from lsq set value, flux set value (Z146.13) and the "slip frequency tem-
perature actual value" (Z19.30). Refer to ZTemperature adaption slip frequencyon
page 508.