108.6 Drive status
This parameter displays the instantaneous state of the drive.
108.7 Comm. source
This parameter controls the access rights to Control Word 1.
Selection of the communication source at axis units:
108.9 Parameter selection status bit 14
This parameter is only relevant for axis units.
Selection of the parameter for the freely definable Status Bit 14 in the drive manager Sta-
tus Word Z108.3.
If at least one bit from the mask Z108.10 is set in the selected parameter, Bit 14 in the
Status Word will be set.
When StatusB14_IdSelect = 0, the mapping for Bit 14 is switched off.
Value Meaning at axis units
0 Not ready to switch on
1 Switch on inhibit
2 Ready to switch on
3 Switched on
4 Operation enabled
5 Operation inhibit active
6 Shut-down active
7 Quick Stop active
14 Error response active
15 Error
Bit # Meaning at axis units
0 1: Motor control via ProDrive/ Fieldbus
15 ... 1 Reserved