Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
355
of 814
3
T
Ramp up
= Ramp-up time Z110.6
T
Ramp down
= Ramp-down time Z110.7
Figure 88: Trapezoidal Profile of Ramp Function Generator
S-Curve Profile Acceleration and braking are introduced more smoothly with the S-Curve profile.
The time to reach maximum acceleration or deceleration is set using the S-Curve time.
The maximum value of the accelerations is determined by the ramp-up time or the ramp-
down time. The S-Curve time can be set separately for the ramp-up and the ramp-down.
The ramp-up or ramp-down time resulting from a change to the input set value of 100 %
can be found from
T
Ramp-upTotalTime
= T
Ramp-upTime
+ T
SCRamp-upTime
or
T
Ramp-downTotalTime
= T
Ramp-downTime
+ T
SCRamp-downTime

Table of Contents