EasyManua.ls Logo

Baumuller b maXX BM5800 - Page 99

Baumuller b maXX BM5800
816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the Software Modules and Parameters
Parameter manual b maXX BM5800
Document No.: 5.16029.03
99
of 814
3
The cold slip frequency must be lower than the warm slip frequency (Z107.16).
At asynchronous motors without an electronic type plate the parameter must be set man-
ually.
107.16 Slip frequency (warm)
(this is relevant at asynchronous motors with encoder, only)
Slip frequency of the motor at nominal torque current and nominal flux (magnetic flux =
100%) according to the slip temperature (warm)
Z107.18. The parameters 107.16 and
Z107.18 support the temperature adaption characteristic of the slip frequency. Refer to
"Slip frequency temperature actual value" Z19.30.
The slip frequency when warm must be higher than the slip frequency when cold
(
Z107.15).
At asynchronous motors without an electronic type plate the parameter must be set man-
ually.
107.17 Slip temperature (cold)
(this is relevant at asynchronous motors with an encoder if the temperature monitoring is
activated,
Z128.2 bit 0 to 7).
Temperature specification for which the motor slip frequency when cold (Z107.15) ap-
plies, see also Z19.30.
The cold slip temperature must be lower than the warm slip temperature (Z107.18).
At asynchronous motors without an electronic type plate the parameter must be set man-
ually.
107.18 Slip temperature (warm)
(this is relevant at asynchronous motors with an encoder if the temperature monitoring is
activated,
Z128.2 bit 0 to 7).
Temperature specification for which the motor slip frequency when warm (Z107.16) ap-
plies, see also Z19.30.
The slip temperature when warm must be higher than the slip temperature when cold
(
Z107.17).
At asynchronous motors without an electronic type plate the parameter must be set man-
ually.

Table of Contents

Related product manuals