Example
To configure a “two rates three color” flow meter:
DGS-3620-28SC:admin# config egress_flow_meter profile_id 1 access_id 1 tr_tcm
cir 1000 cbs 200 pir 2000 pbs 200 exceed replace_dscp 21 violate drop
command: config egress_flow_meter profile_id 1 access_id 1 tr_tcm cir 1000 cbs
200 pir 2000 pbs 200 exceed replace_dscp 21 violate drop
Success.
DGS-3620-28SC:admin#
6-7 show egress_flow_meter
Description
This command is used to display the egress flow-based metering configuration.
Format
show egress_flow_meter {[profile_id <value 1-4> | profile_name <name 1-32>] {access_id
<value1-128>}}
Parameters
profile_id - (Optional) Specifies the index of access list profile.
<value 1-4> - Enter the profile ID used here. This value must be between 1 and 4.
profile_name - (Optional) Specifies the name of the profile.
<name 1-32> - Enter the profile name used here. This name can be up to 32 characters long.
access_id - (Optional) Specifies the access ID.
<value 1-128> - Enter the access ID used here. This value must be between 1 and 128.
Restrictions
None.
Example
To display current egress flow meter table:

Table of Contents

Other manuals for D-Link xStack

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link xStack and is the answer not in the manual?

D-Link xStack Specifications

General IconGeneral
BrandD-Link
ModelxStack
CategorySwitch
LanguageEnglish

Related product manuals