EasyManua.ls Logo

D-Link xStack - Chapter 36 External Alarm Commands

D-Link xStack
1284 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
488
Chapter 36
External Alarm
Commands
config external_alarm {unit <unit_id>} channel <value 1-4> message <sentence 1-128>
show external_alarm {unit <unitlist>}
36-1 config external_alarm
Description
This command is used to configure external alarm message for a channel.
The source of alarm is located outside of the switch. They are monitored via pre-defined
connection channels, with each channel representing a specific alarm event. This command allows
the user to define the alarm event associated with each channel.
Format
config external_alarm {unit <unit_id>} channel <value 1-4> message <sentence 1-128>
Parameters
unit - Specifies the unit to display.
<unit_id> - Specifies the switch in the switch stack.
channel - Specifies which channel is selected to configure.
<value 1-4> - Enter the value of the channel number to be used here.
message - Alarm messages to display on console, log and trap.
<sentence 1-128> - Enter up to 128 characters here for the message to be displayed.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To configure an alarm message for channel 1 of unit 2:
DGS-3620-28SC:admin# config external_alarm unit 2 channel 1 message External
Alarm: UPS is exhausted!
Command: config external_alarm unit 2 channel 1 message External Alarm: UPS is
exhausted!
Success.
DGS-3620-28SC:admin#

Table of Contents

Other manuals for D-Link xStack

Related product manuals