xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
18
2-11 config temperature threshold
Description
This command is used to configure the warning temperature high threshold or low threshold. When
temperature is above the high threshold or below the low threshold, SW will send alarm traps or
keep the logs.
Format
config temperature threshold {high <temperature -500-500> | low <temperature -500-500>}(1)
Parameters
high - Specifies the high threshold value. The high threshold must bigger than the low threshold.
<temperature -500-500> - Enter the high threshold value. This value must be between -500
and 500.
low - Specifies the low threshold value.
<temperature -500-500> - Enter the low threshold value. This value must be between -500
and 500.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To configure a warming temperature threshold high of 80:
DGS-3620-28SC:admin#config temperature threshold high 80
Command: config temperature threshold high 80
Success.
DGS-3620-28SC:admin#
2-12 show serial_port
Description
This command is used to display the current console port setting.
Format
show serial_port
Parameters
None.

Table of Contents

Other manuals for D-Link xStack

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link xStack and is the answer not in the manual?

D-Link xStack Specifications

General IconGeneral
BrandD-Link
ModelxStack
CategorySwitch
LanguageEnglish

Related product manuals