xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
232
Parameters
trap - Specifies the trap state.
log - Specifies the log state.
none - Specifies neither attack_detected nor attack_cleared is trapped or logged.
attack_detected - Specifies events will be logged or trapped when the BPDU attacks is detected.
attack_cleared - Specifies events will be logged or trapped when the BPDU attacks is cleared.
both - Specifies the events of attack_detected and attack_cleared shall be trapped or logged.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To configure the BPDU protection trap state as both for the entire switch:
DGS-3620-28SC:admin#config bpdu_protection trap both
Command: config bpdu_protection trap both
Success.
DGS-3620-28SC:admin#
14-4 enable bpdu_protection
Description
This command is used to enable BPDU protection globally for the entire switch.
Format
enable bpdu_protection
Parameters
None.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To enable BPDU protection for the entire switch:
DGS-3620-28SC:admin#enable bpdu_protection
Command: enable bpdu_protection
Success.
DGS-3620-28SC:admin#