xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
267
DGS-3620-28SC:admin#cfm dm 00-01-02-03-04-05 mepname mep1 period:interval
1sec:10sec percentile 75 pdu_priority 7
Command: cfm dm 00-01-02-03-04-05 mepname mep1 period:interval 1sec:10sec
percentile 75 pdu_priority 7
Success.
DGS-3620-28SC:admin#
16-32 cfm lm
Description
This command is used to start a frame loss measurement test.
Format
cfm lm <macaddr> [mepname <string 32> | mepid <int 1-8191> md [<string 22> | md_index
<uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]] {period [100ms |
1sec | 10sec] | pdu_priority <int 0-7>}
Parameters
<macaddr> - Enter the destination MAC address.
mepname - Specifies the MEP name.
<string 32> - Enter the MEP name. This name can be up to 32 characters long.
mepid - Specifies the MEP ID.
<int 1-8191> - Enter the MEP ID. This value must be between 1 and 8191.
md - Specifies the Maintenance Domain name.
<string 22> - Enter the Maintenance Domain name. This name can be up to 22 characters
long.
md_index - Specifies the Maintenance Domain index.
<uint 1-4294967295> - Enter the Maintenance Domain index. This value must be between 1
and 4294967295.
ma - Specifies the Maintenance Association name.
<string 22> - Enter the Maintenance Association name. This name can be up to 22
characters long.
ma_index - Specifies the Maintenance Association index.
<uint 1-4294967295> - Enter the Maintenance Association index.
period - (Optional) Specifies the transmission period of LMM message.
100ms - Specifies that the transmission period will be 100ms.
1sec - Specifies that the transmission period will be 1sec.
10sec - Specifies that the transmission period will be 10sec.
pdu_priority - (Optional) Specifies the 802.1p priority which is set in the DMM message
transmitted by the MEP.
<int 0-7> - Enter the 802.1p priority which is set in the DMM message transmitted by the
MEP. This value must be between 1 and 7.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command. (EI Mode Only