AV7000 LINEAR CAMERA REFERENCE MANUAL
6.3.5 Cleaning the Tachometer
If your application uses the tachometer option for tracking purposes, be sure to clean the
tachometer wheels periodically as outlined below.
1. Turn off the product transport.
2. Turn off the barcode reader by disconnecting the power source.
3. Using a clean, soft cloth, wipe the wheels of the tachometer clean using a mild detergent
solution.
4. Before restarting the system, be sure the tachometer is making good contact with the
product transport.
5. Verify tachometer operation.
Figure 147: Tachometer Wheel
6.3.6 Tighten Mounting Hardware
1. Check all AV7000, Deflection Mirrors, CBX connection boxes, and power supply
mounting hardware as applicable. Tighten as necessary. Do not over-tighten. Be sure not
to disturb the equipment’s alignment as it relates to the product transport.
2. Check the mounting hardware of the Photoelectric Sensor (if this option is being used).
Tighten as necessary. Do not over-tighten.
3. Check the mounting hardware of the tachometer (if this option is being used). Tighten as
necessary. Do not over-tighten.
6.3.7 Checking Barcode Reading System Connections
This is a safety check recommended for harsh environments where vibration may be a
problem. (See Chapter 3, Electrical Installation.)
1. Check all wiring connections to the camera and illumination connector panels. Tighten
any loose connections as necessary. Do not over-tighten.