MAINTENANCE
297
6
2. Check all wiring connections to the CBX connection box. Tighten any loose connections
as necessary. Do not over-tighten.
3. Check all cabling/conduit for signs of wear/damage. Repair/replace any damaged cable
connections as necessary.
0.
6.3.8 Verify Barcode Reader Operation
If after performing maintenance, the imaging system continues to perform below the normal
operations experienced with the system under normal daily conditions, contact Datalogic
through our website at www.datalogic.com.
6.3.9 Verify Photoelectric Sensor Operation
1. Block the Photoelectric Sensor emitter beam to confirm it is aligned properly with the
reflector.
2. Verify that the TRIGGER LED on camera lights when photoelectric sensor beam is
blocked.
If the photoelectric sensor’s LED does not change status, adjust the photoelectric sensor
so that it is properly aligned with the reflector.
If the TRIGGER LED on the barcode reader does not light when the photoelectric
sensor’s beam is blocked, check the cabling between the photoelectric sensor and CBX
connection box for damage.
0.
6.3.10 Verify Tachometer Operation
Rotate the tachometer wheel slowly.
The TACH LED on camera’s connector panel should flash indicating the tachometer is
operational.

Table of Contents

Other manuals for Datalogic AV7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic AV7000 and is the answer not in the manual?

Datalogic AV7000 Specifications

General IconGeneral
BrandDatalogic
ModelAV7000
CategoryDigital Camera
LanguageEnglish

Related product manuals