AV7000 LINEAR CAMERA REFERENCE MANUAL
84
3
3.11.5 Digital Output Configuration from CBX510
The CBX510 includes an OUTPUTS block for wiring relays as needed for external
accessories.
Schematics for Isolated and Non-Isolated digital outputs are provided below.
Outputs 1 - 3
Figure 84: OUTPUTS Block
Maximum Voltage 30 Vdc
Collector Current (pulse) 130 mA Max.
Collector Current (continuous) 40 mA Max.
Saturation Voltage (VCE) 1 V at 10 mA Max.
Maximum Power Dissipation 90 mW at 50°C
(Ambient temperature)
3.11.6 Unpowered Outputs
Figure 85: Unpowered Outputs
NPN
PNP