EasyManuals Logo

Datalogic AV7000 Reference Manual

Datalogic AV7000
337 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #321 background imageLoading...
Page #321 background image
TROUBLESHOOTING
309
7
e-Genius
Description
Type
Explanation
Possible Cause
Solution
Error: No valid
temperature for laser #1
Error
The RangeFinder is
unable to read the laser
temperature.
Internal RangeFinder
failure.
Cycle the unit’s power. If the
error persists, replace the
RangeFinder and/or contact
Datalogic Support.
Error: No valid
temperature for laser #2
Error
The RangeFinder is
unable to read the laser
temperature.
Internal RangeFinder
failure.
Cycle the unit’s power. If the
error persists, replace the
RangeFinder and/or contact
Datalogic Support.
Error: Sensor data
always from DOE #1
Error
Object data is always
being detected by
DOE#1.
Object stuck on belt.
Obstruction in the DOE
laser pattern. Beam
blockers not set
correctly.
Verify there are no objects or
obstructions in the DOE
laser pattern. Verify the
Beam blockers are set
correctly. Cycle the unit’s
power. If the error persists,
replace the RangeFinder
and/or contact Datalogic
Support.
Error: Sensor data
always from DOE #2
Error
Object data is always
being detected by
DOE#2.
Object stuck on belt.
Obstruction in the DOE
laser pattern. Beam
blockers not set
correctly.
Verify there are no objects or
obstructions in the DOE
laser pattern. Verify the
Beam blockers are set
correctly. Cycle the unit’s
power. If the error persists,
replace the RangeFinder
and/or contact Datalogic
Support.
Error: Sensor or laser
problem (no
codewords)
Error
The RangeFinder is
unable to see the laser
patterns.
There is an obstruction
preventing the sensor
(in the center of the
RangeFinder) to see
the laser patterns. An
internal Sensor error.
The laser patterns are
not present or blocked.
Verify there are no
obstructions blocking the
view of the sensor. Verify
there are no obstructions
blocking the laser pattern
generators. Cycle the unit’s
power. If the error persists,
replace the RangeFinder
and/or contact Datalogic
Support.
Error: Tach or Tach
Sync problem (invalid
speed)
Error
The RangeFinder
missed a tach sync
pulse. The current tach
value does not match
the tach value in the
tach sync message.
Noise on the Ethernet
cable connected to the
RangeFinder or the
tachometer. Device
connected without a
breakout cable
connected to eliminate
tach and tach sync.
Make sure cables are not
running too close to a motor.
Make sure a breakout cable
is used when a computer is
attached.

Table of Contents

Other manuals for Datalogic AV7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic AV7000 and is the answer not in the manual?

Datalogic AV7000 Specifications

General IconGeneral
BrandDatalogic
ModelAV7000
CategoryDigital Camera
LanguageEnglish

Related product manuals