Chapter 8 Logic Instructions
8-77
8_
FB/FC
Explanation
Applicable model
FC
MODTURN finds the signed integral part for modulo division of two floating-
point variables or constants.
DVP15MC11T
DVP15MC11T-06
Parameters
Parameter
name
Meaning
Input/
Output
Description Valid range
In1 Input value Input Input value
Depends on the data type of
the variable that the input
parameter is connected to.
In2 Modulo range Input Modulo range
Depends on the data type of
the variable that the input
parameter is connected to.
0 is excluded.
Out
Number of
modulo
rotations
Output Number of modulo rotations
Depends on the data type of
the variable that the output
parameter is connected to.
Boolean
Bit string Integer
Real
number
Time, date
String
BOOL
BYTE
WORD
DWORD
LWORD
USINT
UINT
UDINT
ULINT
SINT
INT
DINT
LINT
REAL
LREAL
TIME
DATE
TOD
DT
STRING
In1
In2
Out
Note:
The symbol indicates that the parameter is allowed to connect to the variable or constant of the data
type.
Function Explanation
MODTURN is used to carry out modulo division of two floating-point variables or constants and get
the signed integral component. The result is output to Out. The number of modulo rotations of an
axis can be calculated according to its set absolute position.
The input variable and input variable or the input variable and output variable are allowed to be of
different data types in this instruction.
MODTURNS
EN ENO
In1 Out
In2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-15MC Series and is the answer not in the manual?

Delta DVP-15MC Series Specifications

General IconGeneral
BrandDelta
ModelDVP-15MC Series
CategoryController
LanguageEnglish

Related product manuals