DVP-15MC Series Motion Controller Operation Manual 
8-92 
  Users can choose different data types for the input parameter in this instruction. But the data type 
of the output parameter is restricted to LREAL. An error will occur during the compiling of the 
software if the data type of the output parameter is not LREAL.   
  Precautions for Correct Use 
  The input variable is not allowed to omit. An error will occur during the compiling of the software if 
the input variable is omitted. But the output variable is allowed to omit. 
  Programming Example   
  The data types of variables TAN _In and Out1 are INT and LREAL respectively. The value of Out1 
is 0.648360827459087 if the value of TAN _In is 10 when TAN _EN changes to TRUE. The value 
of Out1 is -0.648360827459087 as TAN _In is -10. 
  Variable 1 
  Variable 2 
TAN_In
INT
-10 
Out1
LREAL
-0.648360827459087 
  The program 
 
1
TAN
EN ENO
In Out
TAN_EN
TAN_In Out1