Chapter 10 Motion Control Function
10-33
1
Note3: When Status of MC_Power is FALSE, the MC_Reset instruction is used to reset the axis to
the Disabled state.
Note4: When Enable and Status of MC_Power are TRUE, the MC_Reset instruction is used to
reset the axis to the Standstill state.
Note5:The axis enters from Disabled to Standstill state when the MC_Power instruction is used to
enable the axis and Status of MC_Power is TRUE.
Note6:The axis enters from Stopping to Standstill state when Done of MC_Stop is TRUE and
Execute of MC_Stop is FALSE.
No. Axis state Indication
1 StandStill Pre-execution state
2 Disabled No-execution state
3 ErrorStop Error state
4 Stopping Stop state
5 Homing Homing state
6 Discrete Motion Discrete motion state
7 Continuous Motion Continuous motion state
8 Synchronized Motion Synchronized motion state
Note: Axis state can be judged according to the output parameters of the MC_ReadStatus instruction.
Refer to section 11.3.17 for details on the MC_ReadStatus instruction.