Chapter 11 Motion Control Instructions
11-41
Programming Example 1
The programming example is as follows when one MC_MoveRelative instruction is used.
1. The variables and program
Variable name
Data type
Initial value
Pwr
MC_Power
Axis1 USINT
1
Pwr_En
BOOL
FALSE
Pwr_BM
MC_Buffer_Mode
0
Pwr_Sta BOOL
Pwr_Bsy
BOOL
Pwr_Act
BOOL
Pwr_Err BOOL
Pwr_ErrID
WORD
Rel
MC_MoveRelative
Rel _Ex
BOOL
FALSE
Rel _BM
MC_Buffer_Mode
0
Rel _Done
BOOL
Rel _Bsy
BOOL
Rel _Act
BOOL
Rel _Abt
BOOL
Rel _Err
BOOL
Rel _ErrID
WORD
Position
20000
10000
Distance=10000 Distance=-10000
Position
20000
10000
Start Position
Distance>0 Distance<0
Star t Po sition
Target Position
Target Position
Time Time