Command Line Interface
Command Examples Root> config port speed 4 2g
Root> config port speed 6 negotiate
config.port.type
Syntax name portNumber portType
Purpose This command sets the allowed type for a port.
Description A port can be configured as an F_Port, an E_Port, or a G_Port:
â—† If a port is configured as an F_Port, that port cannot be used as an
interswitch link, but may attach to a device with an N_Port.
â—† If a port is configured as an E_Port, only other switches may
attach to that port.
â—† If a port is configured as a G_Port, either a device or another
switch may attach.
Parameters This command has two required parameters:
Command Example
Root> config port type 4 fport
config.port.show
Syntax show portNumber
Purpose This command displays the port configuration for a single port.
Parameters This command has one parameter:
Command Example
Root> config port show 4
portNumber
Specifies the port number. Valid values for the
DS-32M2 are 0 through 31.
portType
Specifies the type of the port. Valid values are
eport, fport, and gport.
portNumber
Specifies the port number. Valid values for the
DS-32M2 are 0 through 31.