D
D-66 Connectrix DS-32M2 User Guide
Command Line Interface
If State is Segmented E_Port:
0 = Segment not defined
1 = Incompatible operating parameters
2 = Duplicate Domain ID(s)
3 = Incompatible zoning configurations
4 = Build fabric protocol error
5 = No principal switch
6 = No response from attached switch
7 = ELP retransmission failure timeout
If State is Invalid Attachment:
0 = Unknown
1 = ISL connection not allowed on this port
2 = ELP rejected by the attached switch
3 = Incompatible switch at other end of the ISL
4 = External loopback adapter connected to the port
5 = N_Port connection not allowed on this port
6 = Non-EMC switch at other end of the ISL
7 = ISL connection not allowed on this port
8 = ISL connection not allowed to external fabrics
9 = Port binding violationunauthorized WWN
If State is Inactive:
0 = Inactive RC 0
1 = No Serial Number
2 = Feature Not Enabled
3 = Switch Speed Conflict
4 = Optics Speed Conflict

Table of Contents