Indicator Status Description
A
GEL
(Global Error
LED)
off no critical event (non CSS component)
orange on prefailure detected (non CSS component)
orange
flashing
non CSS component failure
Possible reasons:
– sensors report overheating
– sensor is defective
– CPU error
– software reports an error
B
CSS
(Customer
Self Service)
off no critical event (CSS component)
yellow on prefailure detected (CSS component)
yellow
flashing
CSS component failure
C Identification
blue on Localizes the server
blue
flashing
Local monitor off
D Memory
off memory module operational
orange on memory module failure
E System fans
off fan running
orange on fan failure
F PCI card
off PCI card operational
orange on PCI card failure
G AUX power yellow on AUX voltages are within range
H iRMC
green
flashing
iRMC S4 management controller is
operational