Page #325 background imageLoading...
Page #325 background image
TX1330 M1
Upgrade and Maintenance Manual 325
Appendix
Indicator Status Description
A
GEL
(Global Error
LED)
off no critical event (non CSS component)
orange on prefailure detected (non CSS component)
orange
flashing
non CSS component failure
Possible reasons:
– sensors report overheating
– sensor is defective
– CPU error
– software reports an error
B
CSS
(Customer
Self Service)
off no critical event (CSS component)
yellow on prefailure detected (CSS component)
yellow
flashing
CSS component failure
C Identification
blue on Localizes the server
blue
flashing
Local monitor off
D Memory
off memory module operational
orange on memory module failure
E System fans
off fan running
orange on fan failure
F PCI card
off PCI card operational
orange on PCI card failure
G AUX power yellow on AUX voltages are within range
H iRMC
green
flashing
iRMC S4 management controller is
operational

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Server PRIMERGY TX1330 M1 and is the answer not in the manual?

Fujitsu Server PRIMERGY TX1330 M1 Specifications

General IconGeneral
Memory Slots4
Form FactorTower
ChipsetIntel C226
Processor Sockets1
ProcessorIntel Pentium, Intel Celeron
RAID SupportRAID 0, 1, 5, 10
Drive Bays8 x 3.5-inch
Operating System SupportWindows Server, Red Hat, SUSE, VMware