EasyManuals Logo

Hioki PQ3100 User Manual

Hioki PQ3100
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #186 background imageLoading...
Page #186 background image
180
Calculation Formula
8. Power factor (PF), Displacement power factor (DPF)
Wiring
Item
Single phase
2-wire
1P2W
Single phase
3-wire
1P3W
3-phase 3-wire
3P3W2M
3-phase 3-wire
3P3W3M
3-phase 4-wire
3P4W
PF [ ]
PF/Q/S
Calculation
Selection:
RMS value
calculation
PF
1
PF
c
=
c
c
S
P
si
PF
1
PF
2
PF
1
PF
2
PF
3
PF
sum
=
sum
sum
S
P
si
Si
: indicates lag and lead. The sign of reactive power Q (fundamental wave reactive power) is used.
Sign +: lag
Sign −: lead
When
S < |P|
due to the effects of measurement errors or unbalance,
S = |P|
and
PF = 1
.
When
S = 0
, PF is taken as invalid data.
DPF [ ]
PF/Q/S
Calculation
Selection:
Fundamen-
tal wave
calculation
DPF
1
DPF
c
=
)1(
)1(
c
c
S
P
si
DPF
1
DPF
2
DPF
1
DPF
2
DPF
3
DPF
sum
=
)1(
)1(
sum
sum
S
P
si
Si
: indicates lag and lead. The sign of reactive power Q (fundamental wave reactive power) is used.
Sign +: lag
Sign −: lead
(1): indicates the harmonic calculation fundamental wave (1st order)
When
S
c(1)
= 0
,
DPF
is taken as invalid data.
c
: Measurement channel
9. Active energy (WP+/WP−), Reactive energy (WQ_LAG/WQ_LEAD), Apparent energy (WS),
Energy cost (Ecost)
Wiring
Item
Single phase
2-wire
1P2W
Single phase
3-wire
1P3W
3-phase 3-wire
3P3W2M
3-phase 3-wire
3P3W3M
3-phase 4-wire
3P4W
WP+ [Wh]
(consumption)
WP+=
+
h
sum
Pk
1
)(
P(+)
: Only the consumption component of active power (positive component) is used.
WP− [Wh]
(Regeneration)
WP−=
h
sum
Pk
1
)(
P(−)
: Only the regeneration component of active power (negative component) is used.
WQ_LAG
[varh]
(Lag)
WQ_LAG=
h
sum
LAGQk
1
)(
Q(LAG)
: Only the lag component of reactive power is used.
WQ_LEAD
[varh]
(Lead)
WQ_LEAD=
h
sum
LEADQk
1
)(
Q(LEAD)
: Only the lead component of reactive power is used.
WS [VAh]
WS=
h
sum
Sk
1
Ecost
[Variable]
Ecost=
rateWP ×+
rate
: Electrical unit cost (variable setting from 0.00000 to 99999.9/kWh)
k
: Calculation unit time [h],
h
: Measurement duration

Table of Contents

Other manuals for Hioki PQ3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hioki PQ3100 and is the answer not in the manual?

Hioki PQ3100 Specifications

General IconGeneral
BrandHioki
ModelPQ3100
CategoryMeasuring Instruments
LanguageEnglish