Page #76 background imageLoading...
Page #76 background image
70
Recording Settings
6
Enables you to set the method used to start recording.
Manual Recording starts immediately after the [START/STOP] key is pressed.
Specied time
After the [START/STOP] key is pressed, recording starts at the set time. (If
the set time has already passed when the key is pressed, “Interval” starting
method will be used.)
YYYY-MM-DD hh:mm
Interval time
Recording starts at an even time division based on the Recording interval.
If the [START/STOP] key is pressed at the time “10:41:22” with the time
interval set to 10 min, the instrument will enter in the standby state. The
recording will start at “10:50:00.”
If the set recording interval is of 30 s or less, recording will start from the
next zero second.
Repeat
Segments the le every day and repeats the recording.
Sets the Recording period.
If a folder is labeled arbitrarily, data recorded for up to 99 days can be
stored.
After the [START/STOP] key is pressed, recording starts in the Recording
period of the set start date. (If the set time has already passed when the
key is pressed, “Interval” starting method is used.)
The Recording intervals of 1 sec and above are valid.
YYYY-MM-DD
See “7.1 Start and Stop of the Recording” (p. 91).
7
Enables you to set the method used to stop the recording.
Manual Press the [START/STOP] key to stop the recording.
Specied time
Recording stops at the set time.
(If the set time has already passed when recording starts, recording will be
stopped using the “manual” method.)
YYYY-MM-DD hh:mm
Timer
Stops the recording automatically if the set timer time has elapsed.
hhh:mm:ss
Repeat
Displayed when Recording start setting is congured to Repeat.
Recording is stopped if the Recording period of the stop date has passed.
The stop method cannot be changed for repeat recording.
YYYY-MM-DD
See “7.1 Start and Stop of the Recording” (p. 91).
8
Recording start method is displayed for the repeat recording.
Set the recording period.
hh:mm to hh:mm

Table of Contents

Other manuals for Hioki PQ3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hioki PQ3100 and is the answer not in the manual?

Hioki PQ3100 Specifications

General IconGeneral
BrandHioki
ModelPQ3100
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals