NumBufs
(Multipoint
only)
TR(CD)
Configuring
the
Terminal
Table
3-4.
Datacomm Configuration Menu Fields (Continued)
This
field specifies
the
desired
number
of
datacomm
buffers to
be used for
the
terminal.
The
permissible
values
are
2
through
16 (your
actual
choice, however,
can
be affected by
the
selected
buffer
size; see BufSi ze).
The
designated
buffers will be used
for
both
receiving
and
transmitting
data.
Default=2
This
field specifies
the
desired
state
of
the
RS-232C
TR
line
(Data
Terminal
Ready) when
the
terminal
is
first
turned
on
or
when
the
terminal
is reset.
Whenever
the
terminal
performs
a
disconnect,
it
also
returns
TR
to
the
state
specified by
this
field.
For
configurations
in
which
the
Full
Duplex
Hardwired
menu
((RecvPac i ng" field is
set
to
((TR(
CD)",
the
TR
line
is
used
to
control receive pacing.
Values:
Hi
Lo
Default=Hi
Check
Parity
(Pt-to-pt
only)
BCC
(Multipoint
only)
This
field is used for
enabling
or
disabling
the
parity
check
feature
for
data
characters
received
over
the
datacomm
line.
Note
that
if
the
((Pa
r i t y" field (above)
is
set
to
((None",
this
field is ignored.
If
the
((Da
taB
its"
field is
set
to ((8",
this
field
must
be
set
to
uNone".
Yes:
enable
No:
disable
Default=No
Selects CRC (cyclic
redundancy
check)
or
LRC <longitudinal
redundancy
check)
type
ofblock checking.
The
selection
used
should
be
the
same
as
that
used
by
the
drive'!
program
in
the
host
computer. (The
HP
1000
and
HP
3000
computers
use
CRC.)
3-19