EasyManuals Logo

Huawei iMaster NetEco V600R021C10 User Manual

Huawei iMaster NetEco V600R021C10
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #154 background imageLoading...
Page #154 background image
Prerequisites
The management domain adapter has been precongured or installed.
Context
The management domains include Park, Building, Room, ContainerDC,
Subnet, NetecoSite, FusionModule500, Modular, Room-ShapeNode, and
Building-ShapeNode. You are advised to plan the subordinate relationship
between management domains and devices before performing operations.
The NetEco is
precongured with management domains such as cabinets,
battery cabinets, buildings, containers, oors, FusionModule500, smart
modules, NetEco sites, parks, PDUs, equipment rooms, and subnets. To use
more management domains, you need to install the corresponding adapter
software package on the NetEco.
Procedure
Step 1 Log in to the NetEco client.
Step 2 On the main menu, choose Device Management >
Conguration > Planning
Conguration.
Step 3 Choose the upper-layer node of the management domain to be added in the
navigation tree on the left.
Step 4 In the Domain area on the lower left of the page, drag a management domain
icon to the required position in the planning
conguration area.
NO TE
You can adjust the shape of Room, Room–ShapeNode, Building–ShapeNode, Floor
ShapeNode, Container–ShapeNode, and NetecoSite by:
1. Hold down Shift and click the frame to add a yellow dot.
2. Click and move the yellow dot to design an irregular polygon.
3. To delete a management domain, click the domain icon and select Delete under
.
Step 5 In the right side of the view area, set Management Info.
NO TE
You can congure Management Info, Electricity Info, and Refrigeration Info for the
equipment room management domain.
Step 6 Click
on the toolbar to save the settings.
Step 7 Repeat steps Step 3 to Step 6 until the
conguration is complete.
----End
6.1.8.2 Example: Adding a Smart Module
This section describes how to create a module in the root node, subnet, equipment
room, container, or site management domain.
iMaster NetEco
Device Installation and Commissioning Guide (Data
Center) 6 Adding Devices
Issue 02 (2021-05-12) Copyright © Huawei Technologies Co., Ltd. 143

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei iMaster NetEco V600R021C10 and is the answer not in the manual?

Huawei iMaster NetEco V600R021C10 Specifications

General IconGeneral
BrandHuawei
ModeliMaster NetEco V600R021C10
CategoryNetwork Hardware
LanguageEnglish

Related product manuals