v 2.3 — September 2015 Altanium Delta3
118 Boost Timer Settings
To cancel the remote standby duration timer at any time, touch the Start or Stop buttons.
10.1.8 Boost Timer Settings
To increase the temperatures in the mold for a certain period of time, set the boost timers
associated with each boost function. Once the system enters boost, the timer will start. When
the timer finishes, the temperatures will return to the normal setpoint.
10.1.8.1 Setting the Manual Boost Duration Timer
Use the manual boost duration timer setting to set a duration period for the zones to heat up
to the manual boost setpoint limit.
To set the manual boost duration timer, do the following:
1. On the System Setup screen, under Manual Standby and Boost, touch the Manual
Boost Duration Timer field.
2. Enter the time required in the format HHMMSS.
3. Touch the Accept button.
10.1.8.2 Setting the Remote Boost Duration Timer
The input option settings determine how the system reacts when it receives remote boost
input.
NOTE:If the system is not equipped with remote boost, only the Manual Boost Duration
Timer field is displayed on the System Setup screen.
---- 0:00:00 0:00:00 ON/OFF ---- System enters Standby until the input
signal is not active.
---- 0:00:00 X:XX:XX ON/OFF ---- System enters Standby until the input
signal is not active or the timer expires.
---- X:XX:XX X:XX:XX ON/OFF ---- System delays for specified time and
then enters Standby until the signal is
not active or the timer expires.
---- X:XX:XX 0:00:00 ON/OFF ---- System delays for specified time and
then enters Standby until the input
signal is not active.
---- ---- ---- Direct ---- System enters Standby until the input
signal is not active. If the input signal is
active when the system is started, it
will immediately go into Standby
mode.
Table 10-3 Remote Standby Operational Description (Continued)
Manual
Time
Delay
Time
Remote
Time
Input
Mode
Cycle
Enabled