v 2.3 — September 2015 Altanium Delta3
68 Setpoint Limits
7.5.3 Setpoint Limits
7.5.4 Manual Standby Fields
7.5.5 Manual Boost Fields
Item Description
Temperature Minimum
The minimum and maximum values limit what temperature the
temperature setpoint can be changed to.
Temperature Maximum
Power Minimum
The minimum and maximum values limit what temperature the power
setpoint can be changed to.
Power Maximum
Item Description
Temperature The temperature all zones are set to when the Standby button is
touched. This setting can be used to lower all zone temperatures to their
manual standby temperature setpoint until the timer expires or the user
touches the Standby button again. Possible values are 0 to 500°C or 32 to
932°F. The default value is 121°C or 250°F.
Temperature Minimum
Limits the range that can be entered for Standby temperature.
Temperature Maximum
Power The power output all zones are set to when the Standby button is
touched. This setting can be used to lower all zone power setpoints to
their manual standby power setpoint until the timer expires or the user
touches the Standby button again. Possible values are 0% – 100%. The
default value is 10%.
Power Minimum
Limits the range that can be entered for Standby power.
Power Maximum
Item Description
Temperature The temperature all zones are set to when the Boost button is touched.
This setting raises all zones to their manual boost setpoint until the timer
expires or the user touches the Boost button again. Possible values are 0
to 500°C or 32 to 932°F. The default value is No Change.
Temperature Minimum
Limits the range that can be entered for Boost Temperature.
Temperature Maximum