User Guide v 2.3 — September 2015 Making Adjustments
7.5.6 Remote Standby Fields
7.5.7 Remote Boost Fields
Power The power values all zones are set to when the Boost button is touched.
This setting raises all zones to their manual boost setpoint until the timer
expires or the user touches the Boost button again. Possible values are
0% – 100%. The default value is 90%.
Power Minimum
Limits the range that can be entered for Boost power.
Power Maximum
Item Description
Item Description
Temperature Remote standby is initiated via a digital input signal from the IMM. This
setting lowers all zones to their remote standby setpoint until the timer
expires or the input is inactive. Possible values are 0 to 500°C or 32 to
932°F. The default value is 121°C or 250°F.
Temperature Minimum
Limits the range that can be entered for Remote Standby Temperature.
Temperature Maximum
Power Remote standby is initiated via a digital input signal from the IMM. This
setting lowers all zones to their remote standby setpoint until the timer
expires or the input is inactive. Possible values are 0% – 100%. The default
value is 10%.
Power Minimum
Limits the range that can be entered for Remote Standby Power
Power Maximum
Item Description
Temperature Remote boost is initiated via a digital input signal from the IMM. This
setting raises all zones to their remote boost setpoint until the timer
expires or the input is inactive. Possible values are 0 to 500°C or 32 to
932°F. The default value is No Change.
Temperature Minimum
Limits the range that can be entered for Remote Boost Temperature.
Temperature Maximum
Power Remote boost is initiated via a digital input signal from the IMM. This
setting raises all zones to their remote boost setpoint until the timer
expires or the input is inactive. Possible values are 0% – 100%. The default
value is 90%.