Outputs 211
User Guide v 2.3 — September 2015 UltraSync-E, If Equipped
16.6.2 Outputs
Use the Outputs screen to configure the digital output signals to the injection molding
machine.
Figure 16-11 Digital Outputs Screen
Signal Name Description Pin (s)
IMM Signal Reference Reference signal from IMM for dry contacts. 5, 6
Fault Stop Immediate Active when clamp motion is permitted. These
contacts are opened when an immediate stop is
required for the machine, due to a fault or alarm on
the controller.
7, 8
Ready and Engaged Active when controller is enabled with no faults, in
auto/engaged mode.
6, 9
Valve Stems at Open Active when all of the following conditions are true:
-Valve gate controller is ready and engaged
-Valve stems are at open position
-Valve gate controller is in auto/engaged mode
This signal can be used to provide injection
permission to the IMM.
6, 10
Valve Stems at Close Active when valve gate stems are at closed position,
and controller is enabled.
6, 11