v 2.3 — September 2015 Altanium Delta3
120 Power Deviation Settings
Remote Boost can be cancelled at any time by touching the Start or Stop buttons.
10.1.9 Power Deviation Settings
The Power Deviation alarm notifies the operator when the power output percentage on any
zone deviates a specified amount while running under normal conditions. This information
can be used to detect plastic leaks in the nozzle bore or manifold pocket.
To setup or make a change to this feature, do the following:
1. On the System Setup screen, under Power Deviation, touch the Setup Alarm button.
2. Change the desired settings per Table 10-6.
3. Accept changes and touch the Exit button.
NOTE:Before the Power Deviation routine can be executed, at least one zone in the system
must be classified based on similar function and operation.
Table 10-5 Remote Boost Operational Description
Manual
Time
Delay
Time
Remote
Time
Input
Mode
Operation - Boost Button Select
---- 0:00:00 0:00:00 Trigger System will not enter Boost since no timers are set.
---- 0:00:00 X:XX:XX Trigger System immediately enters and remains in Boost
until the timer expires.
---- X:XX:XX X:XX:XX Trigger System delays for specified time and then enters
Boost until the timer expires.
---- X:XX:XX 0:00:00 Trigger System delays for specified time and then enters
Boost indefinitely.
---- 0:00:00 0:00:00 ON/OFF System enters Boost until the input signal is not
active.
---- 0:00:00 X:XX:XX ON/OFF System enters Boost until the input signal is not
active or the timer expires.
---- X:XX:XX X:XX:XX ON/OFF System delays for specified time and then enters
Boost until the input signal is not active or the
timer expires.
---- X:XX:XX 0:00:00 ON/OFF System delays for specified time and then enters
Boost until the signal is not active.
---- ---- ---- Direct System enters Standby until the input signal is not
active. If the input signal is active when the system
is started, it will immediately go into Standby
mode.