Process History Screen 155
User Guide v 2.3 — September 2015 Data Recording
12.2 Process History Screen
On the Process History screen, the data is presented zone by zone. The Process History
screen provides a visual summary of the recorded operation, noting power usage,
temperature fluctuations, setpoint values, pressures, positions and times. A detailed textual
representation is offered for specific times.
Available process variables for heat zones:
Actual Current
Actual Earth Leakage (displayed only when configured in System Setup)
Actual Power
Actual Temperature
Actual Temperature Setpoint
Actual Voltage
Available process variables for UltraSync-E:
Close Position
Closing Duration
Open Position
Opening Duration
Peak Closing Force
Peak Opening Force
Cycle Time
The process history holds 10,000 records. Records contain values for all of the logged values
for each zone in the system. A frequent sampling rate will fill the database faster than a
slower sampling rate.