76 Changing the Manual Standby and Remote Standby Setpoint Limits
7.5.16.2 Changing the Manual Standby and Remote Standby Setpoint Limits
It may be necessary to lower the temperatures in the mold for a period of time. This can be
done on the system header by selecting the Manual Standby button (or Remote Standby
from a remote location as an option) without needing to change the normal setpoint. Specify
the desired temperatures for the heaters in the mold to cool down to when the system is in
Standby; both manual standby and remote standby. The default setting for both the manual
and remote standby setpoints is 121 °C (250 °F).
7.5.16.2.1 Changing the Manual Standby Setpoint Limits
To change a standby setpoint and standby setpoint limits for a zone, do the following:
1. Touch the zone to be changed.
2. Touch the Temperature Setpoint field and enter a value.
3. Touch the Accept button.
4. Touch the Temperature Minimum field and enter a value.
5. Touch the Accept button.
6. Touch the Temperature Maximum field and enter a value.
7. Touch the Accept button.
8. Touch the Power Setpoint field and enter a value.
9. Touch the Accept button.
10. Touch the Power Minimum field and enter a value.
11. Touch the Accept button.
12. Touch the Power Maximum field and enter a setpoint value.
13. Touch the Accept button.
7.5.16.2.2 Changing the Remote Standby Setpoint Limits
To change a remote standby setpoint and remote standby setpoint limits for a zone, do the
following:
1. Touch the zone to be changed.
2. Touch the Temperature Setpoint field and enter a value.
3. Touch the Accept button.
4. Touch the Temperature Minimum field and enter a value.
5. Touch the Accept button.
6. Touch the Temperature Maximum field and enter a value.
7. Touch the Accept button.
8. Touch the Power Setpoint field and enter a value.
9. Touch the Accept button.
10. Touch the Power Minimum field and enter a value.
11. Touch the Accept button.