Zone Alarm Control 133
User Guide v 2.3 — September 2015 System Setup Screen
Figure 10-16 System Setup Screen - Zone Alarm Control
1. Zone Alarm Control
Table 10-7 Zone Alarm Control Settings
Setting Description
Alarm Sensitivity Determines the duration of time the system has
to stay in an error condition before it is declared
an alarm. The default value is 2 seconds and the
valid range is from 2 to 60 seconds.
Maximum Temperature Limit This value is interpreted as the number of
degrees over the setpoint the Maximum
Temperature Alarm is activated. This alarm is
used as a failsafe warning if an Abort Over
Temperature alarm is ignored. The default value
is 111°C and the valid range is 1 to 500°C.