Staging Screen 137
User Guide v 2.3 — September 2015 System Setup Screen
Figure 10-18 Staging Screens - Startup and Shutdown
Item Description
Staged Startup Enable Enables or disables the staged startup sequence.
Run Last Stage Indefinitely If this setting is enabled, all zones in the last assigned stage will
not change to their normal setpoint once all zones have achieved
the stage setpoint and the soak timer has expired.
Stage x Soak Timer The amount of time at each stage the zones “soak” at their stage
setpoints before the next stage begins.
Stage x Temperature The temperature setpoint that the zone heats to during stage x.